Heating Tests
 
Click Here To Visit Our Sponsor
Click Here To Visit Our Sponsor

Home     Search     Ask the Expert     Newsletter      Links      Site Map      Contact Us

Product Design      EMC Guide      National Variants     Telecoms Design Guide      FAQ

Click here to order standards from

Advertise with i-Spec          Contact  advert@i-spec.com for details



Note that references are to IEC 60950 Third Edition 1999-04. Where the references in the Second Edition differ, they appear in parentheses.


REQUIREMENT

In normal use, equipment and its component parts shall not attain excessive temperatures.


TEST METHOD

The product is operated under conditions of normal load and the temperatures of components, enclosure etc. are measured. Operation continues until temperatures stabilise. Table 4A (Table 16) of the standard specifies maximum allowed temperature rises for various parts and materials.


REFERENCE

Complete requirements are given in IEC 60950, Clause 4.5 (5.1).


Subscribe to our newsletter:
Enter your
email address

subscribe
unsubscribe
 

IEC 60950

Basics

Product Design

Telecoms Design Guide

EMC Guidebook

 

  Disclaimer and Acknowledgment   

© i-Spec.com Ltd. 1999-2004. All rights reserved.

All extracts from the publication IEC 60950 have been reproduced by kind permission of the International Electrotechnical Commission (IEC). Copyright © IEC, Geneva, Switzerland.