Steady Force
 
Click Here To Visit Our Sponsor
Click Here To Visit Our Sponsor

Home     Search     Ask the Expert     Newsletter      Links      Site Map      Contact Us

Product Design      EMC Guide      National Variants     Telecoms Design Guide      FAQ

Click here to order standards from

Advertise with i-Spec          Contact  advert@i-spec.com for details



Note that references are to IEC 60950 Third Edition 1999-04. Where the references in the Second Edition differ, they appear in parentheses.


REQUIREMENT

Enclosures shall have adequate mechanical strength and shall be so constructed as to withstand such rough handling as may be expected in normal use.


TEST METHOD

A force of 250 N is applied to external enclosures for a period of 5 seconds via a circular plane surface 30 mm in diameter.

Parts of an enclosure in an operator access area, protected by a cover or door are subjected to a force of 30 N applied via a straight unjointed test finger.

After these tests, the product shall not be damaged in any way that would cause a hazard.


REFERENCE

Complete requirements are given in IEC 60950, Clauses 4.2.2 and 4.2.3 and 4.2.4 (4.2.2 and 4.2.3).


Subscribe to our newsletter:
Enter your
email address

subscribe
unsubscribe
 

IEC 60950

Basics

Product Design

Telecoms Design Guide

EMC Guidebook

 

  Disclaimer and Acknowledgment   

© i-Spec.com Ltd. 1999-2004. All rights reserved.