Note that references are to IEC 60950 Third Edition 1999-04. Where the references in the Second Edition differ, they appear in parentheses.


REQUIREMENT

Enclosures shall have adequate mechanical strength and shall be so constructed as to withstand such rough handling as may be expected in normal use.


TEST METHOD

A steel ball of diameter 50 mm and weight 500 g is dropped from a height of 1300 mm on to the enclosure of the product.

A horizontal side is subjected to this test either by rotating the product 90° from its normal position, or by suspending the steel ball from a rope and allowing in to act like a pendulum, falling from a height of 1300 mm on to the side surface of the product.

After this test, the product shall not be damaged in any way that would cause a hazard. In particular, hazardous parts must not be accessible.


REFERENCE

Complete requirements are given in IEC 60950, Clause 4.2.5 (4.2.4).


IEC 60950

Basics

Product Design

Telecoms Design Guide

EMC Guidebook

 

Subscribe to our newsletter:
Enter your
email address

subscribe
unsubscribe
 

  Disclaimer and Acknowledgment   

© i-Spec.com Ltd. 1999-2004. All rights reserved.

All extracts from the publication IEC 60950 have been reproduced by kind permission of the International Electrotechnical Commission (IEC). Copyright © IEC, Geneva, Switzerland.