REQUIREMENT

Enclosures of moulded or formed thermoplastic materials shall be so constructed that any shrinkage or distortion of the material due to the release of internal stresses caused by the moulding or forming operation does not result in the exposure of hazardous parts.


TEST METHOD

The enclosure is heated to 10°C above the hottest temperature recorded on the enclosure during the heating test , but not less than 70°C, for a period of 7 hours, and then allowed to cool to room temperature.

After this test, the product shall not be deformed in any way that would cause a hazard. In particular, hazardous parts must not be accessible.


REFERENCE

Complete requirements are given in IEC 60950, Clause 4.2.7 (4.2.6).


IEC 60950